Skip to main content

Net2 offers end-to-end security for a wide range of applications. Start simple, grow as your needs change. A powerful all-in-one solution that integrates with numerous security brands. In addition to wireless door handles and door entry controllers, Net2 includes a networked access control system. It can be administered using one or more PCs and managed centrally.

Net2 Classic : –

The Net2 Classic Range included:

  • Net2 classic 1 door access control unit 489-334
  • Net2 classic in plastic housing 385-527
  • Net2 classic with 2A PSU in plastic cabinet 411-501
  • Net2 classic with 2A PSU in metal cabinet 411-381

Net2 Nano : –

The Net2 Nano controller is used in conjunction with a Net2 Airbridge connecting it to the Net2 system in places where you can’t feed an RJ45 (e.g exterior gate, secondary building hard to reach warehouse or office door). Basically anywhere its not practical to run a hardwired network point.

Net2 Plus : –

As part of the Net2 system, Net2 Plus is one of the three previously mentioned control units which also include the nano and the net2 classic. The Net2 Plus system incorporates seven different controllers :

In addition to wireless door handles and door entry, Net2 includes a networked access control system. It can be administered using one or more PCs and managed centrally.

Feature Classic Nano Plus
Total users 10,000 10,000 10,000
Total doors Max 500
Max 200 per RS485 data line
Max 200 Max 500 doors
Max 200 per RS485 data line
Max 100 TCP/IP connections
Doors per Access Control Unit (ACU) 1 1 1
Number of tokens 10,000 10,000 10,000
Number of PIN’s 10,000 10,000 10,000
PIN length 4 4 4
Number of codes 50 50 50
Code length 4 – 8 4 – 8 4 – 8
Number of time zones 64 64 64
Number of time slots 2,000 2,000 2,000
Number of access levels 250 250 250
Stored events per ACU 2,454 4.096 2,454
Data retention during a total power loss 1 day 60 days 28 days
Hands free compatible Yes – requires interface Yes – requires interface Yes – requires interface
3rd party readers Yes – If compatible Yes – If compatible Yes
Clock and data Yes Yes Yes
26 bit Wiegand Yes Yes Yes
Custom Wiegand Yes Yes Yes
Door open time Min 1 sec – Max 999,999 sec Min 1 sec – Max 999,999 sec Min 1 sec – Max 999,999 sec
Reader ports per ACU 2 1 2
Readers/Keypads per ACU 4 – check current draw on individual readers 2 – check current draw on individual readers 4 – check current draw on individual readers
Total ACU reader port output current 500 mA 500 mA 500 mA
Software required Net2 v4.14 and above Net2 v4.14 and above
Communication Classic Nano Plus
RS485 Max 200 ACU’s per data line, requires an RS232 to RS485 converter 200 ACU’s per data line
TCP/IP Ethernet Data line requires a TCP/IP to RS485 converter ACU has an on-board TCP/IP to
RS485 converter
TCP/IP nodes Max 100 Max 100
Ethernet network speed 10 Mbit/s – 100 Mbit/s auto MDIX 10 Mbit/s – 100 Mbit/s auto MDIX
Ethernet bandwidth requirement 100 kbit/s 200 kbit/s
DHCP support (fixed IP recommended) Yes
RS485 network speed 115.2 kbit/s
Hardware Classic Nano Plus
12V DC lock output Max 1.1 Amp
Supply voltage Min 11V DC – Max 15V DC Min 11V DC – Max 14.5V DC Min 11V DC – Max 15V DC
Supply current 200 mA 120 mA 200 mA
Relay switchable voltage 24V DC 24V DC 24V DC
Relay switchable current 4 A 2 A 4 A
Alarm output current 1 A 1 A 1 A
Operating temperature – battery limits Min 0°C – Max +55°C Min 0°C – Max +55°C Min 0°C – Max +55°C
Waterproof No – If used externally, it must be protected in a weatherproof housing No – If used externally, it must be protected in a weatherproof housing No – If used externally, it must be protected in a weatherproof housing
Reader cable type Belden 9540 Belden 9540 Belden 9540
Network cable type CAT5 or Belden 8723 CAT5 or Belden 8723
Other hardware features Classic Nano Plus
 
  • Volt free control relay
  • Input for exit button
  • Input for door contact
  • Input for tamper
  • Input for PSU fail
  • Alarm output
  • Volt free control relay
  • Input for exit button
  • Input for door contact
  • Input for tamper
  • Input for PSU fail
  • Alarm output
  • Integrated lock diodes
  • Volt free control relay
  • Input for exit button
  • Input for door contact
  • Input for tamper
  • Input for PSU fail
  • Alarm output
  • Dedicated intruder alarm integrati on port
  • Integrated terminati on resistors